Nodes/IAMCCS-nodes/LoRA Schedule (WAN, hooks)
ComfyUI Node

LoRA Schedule (WAN, hooks)

Different LoRAs on different generations of a loop

By IAMCCS·Created 12 months ago·Updated 5 days ago· 117
LoRA Schedule (WAN, hooks)
  • default_lora
  • linx
  • lora
  • active_slots
  • report
  • linx
◄generation_index0►
◄log_prefixWAN LoRA schedule►
◄model_typeflow►
◄slot_01_lora_nameno►
◄slot_01_strength1.00►
◄slot_01_presetcustom range►
◄slot_01_start0►
◄slot_01_end0►
◄slot_02_lora_nameno►
◄slot_02_strength1.00►
◄slot_02_presetcustom range►
◄slot_02_start1►
◄slot_02_end1►
◄slot_03_lora_nameno►
◄slot_03_strength1.00►
◄slot_03_presetcustom range►
◄slot_03_start2►
◄slot_03_end2►
◄slot_04_lora_nameno►
◄slot_04_strength1.00►
◄slot_04_presetcustom range►
◄slot_04_start3►
◄slot_04_end3►
◄slot_05_lora_nameno►
◄slot_05_strength1.00►
◄slot_05_presetcustom range►
◄slot_05_start4►
◄slot_05_end4►
◄slot_06_lora_nameno►
◄slot_06_strength1.00►
◄slot_06_presetcustom range►
◄slot_06_start5►
◄slot_06_end5►
◄slot_07_lora_nameno►
◄slot_07_strength1.00►
◄slot_07_presetcustom range►
◄slot_07_start6►
◄slot_07_end6►
◄slot_08_lora_nameno►
◄slot_08_strength1.00►
◄slot_08_presetcustom range►
◄slot_08_start7►
◄slot_08_end7►
◄slot_09_lora_nameno►
◄slot_09_strength1.00►
◄slot_09_presetcustom range►
◄slot_09_start8►
◄slot_09_end8►
◄slot_10_lora_nameno►
◄slot_10_strength1.00►
◄slot_10_presetcustom range►
◄slot_10_start9►
◄slot_10_end9►
◄slot_11_lora_nameno►
◄slot_11_strength1.00►
◄slot_11_presetcustom range►
◄slot_11_start10►
◄slot_11_end10►
◄slot_12_lora_nameno►
◄slot_12_strength1.00►
◄slot_12_presetcustom range►
◄slot_12_start11►
◄slot_12_end11►
◄slot_13_lora_nameno►
◄slot_13_strength1.00►
◄slot_13_presetcustom range►
◄slot_13_start12►
◄slot_13_end12►
◄slot_14_lora_nameno►
◄slot_14_strength1.00►
◄slot_14_presetcustom range►
◄slot_14_start13►
◄slot_14_end13►
◄slot_15_lora_nameno►
◄slot_15_strength1.00►
◄slot_15_presetcustom range►
◄slot_15_start14►
◄slot_15_end14►
◄slot_16_lora_nameno►
◄slot_16_strength1.00►
◄slot_16_presetcustom range►
◄slot_16_start15►
◄slot_16_end15►
◄slot_17_lora_nameno►
◄slot_17_strength1.00►
◄slot_17_presetcustom range►
◄slot_17_start16►
◄slot_17_end16►
◄slot_18_lora_nameno►
◄slot_18_strength1.00►
◄slot_18_presetcustom range►
◄slot_18_start17►
◄slot_18_end17►
◄slot_19_lora_nameno►
◄slot_19_strength1.00►
◄slot_19_presetcustom range►
◄slot_19_start18►
◄slot_19_end18►
◄slot_20_lora_nameno►
◄slot_20_strength1.00►
◄slot_20_presetcustom range►
◄slot_20_start19►
◄slot_20_end19►
◄slot_21_lora_nameno►
◄slot_21_strength1.00►
◄slot_21_presetcustom range►
◄slot_21_start20►
◄slot_21_end20►
◄slot_22_lora_nameno►
◄slot_22_strength1.00►
◄slot_22_presetcustom range►
◄slot_22_start21►
◄slot_22_end21►
◄slot_23_lora_nameno►
◄slot_23_strength1.00►
◄slot_23_presetcustom range►
◄slot_23_start22►
◄slot_23_end22►
◄slot_24_lora_nameno►
◄slot_24_strength1.00►
◄slot_24_presetcustom range►
◄slot_24_start23►
◄slot_24_end23►
◄slot_25_lora_nameno►
◄slot_25_strength1.00►
◄slot_25_presetcustom range►
◄slot_25_start24►
◄slot_25_end24►
◄slot_26_lora_nameno►
◄slot_26_strength1.00►
◄slot_26_presetcustom range►
◄slot_26_start25►
◄slot_26_end25►
◄slot_27_lora_nameno►
◄slot_27_strength1.00►
◄slot_27_presetcustom range►
◄slot_27_start26►
◄slot_27_end26►
◄slot_28_lora_nameno►
◄slot_28_strength1.00►
◄slot_28_presetcustom range►
◄slot_28_start27►
◄slot_28_end27►
◄slot_29_lora_nameno►
◄slot_29_strength1.00►
◄slot_29_presetcustom range►
◄slot_29_start28►
◄slot_29_end28►
◄slot_30_lora_nameno►
◄slot_30_strength1.00►
◄slot_30_presetcustom range►
◄slot_30_start29►
◄slot_30_end29►
◄slot_31_lora_nameno►
◄slot_31_strength1.00►
◄slot_31_presetcustom range►
◄slot_31_start30►
◄slot_31_end30►
◄slot_32_lora_nameno►
◄slot_32_strength1.00►
◄slot_32_presetcustom range►
◄slot_32_start31►
◄slot_32_end31►
◄slot_33_lora_nameno►
◄slot_33_strength1.00►
◄slot_33_presetcustom range►
◄slot_33_start32►
◄slot_33_end32►
◄slot_34_lora_nameno►
◄slot_34_strength1.00►
◄slot_34_presetcustom range►
◄slot_34_start33►
◄slot_34_end33►
◄slot_35_lora_nameno►
◄slot_35_strength1.00►
◄slot_35_presetcustom range►
◄slot_35_start34►
◄slot_35_end34►
◄slot_36_lora_nameno►
◄slot_36_strength1.00►
◄slot_36_presetcustom range►
◄slot_36_start35►
◄slot_36_end35►
◄slot_37_lora_nameno►
◄slot_37_strength1.00►
◄slot_37_presetcustom range►
◄slot_37_start36►
◄slot_37_end36►
◄slot_38_lora_nameno►
◄slot_38_strength1.00►
◄slot_38_presetcustom range►
◄slot_38_start37►
◄slot_38_end37►
◄slot_39_lora_nameno►
◄slot_39_strength1.00►
◄slot_39_presetcustom range►
◄slot_39_start38►
◄slot_39_end38►
◄slot_40_lora_nameno►
◄slot_40_strength1.00►
◄slot_40_presetcustom range►
◄slot_40_start39►
◄slot_40_end39►
◄slot_41_lora_nameno►
◄slot_41_strength1.00►
◄slot_41_presetcustom range►
◄slot_41_start40►
◄slot_41_end40►
◄slot_42_lora_nameno►
◄slot_42_strength1.00►
◄slot_42_presetcustom range►
◄slot_42_start41►
◄slot_42_end41►
◄slot_43_lora_nameno►
◄slot_43_strength1.00►
◄slot_43_presetcustom range►
◄slot_43_start42►
◄slot_43_end42►
◄slot_44_lora_nameno►
◄slot_44_strength1.00►
◄slot_44_presetcustom range►
◄slot_44_start43►
◄slot_44_end43►
◄slot_45_lora_nameno►
◄slot_45_strength1.00►
◄slot_45_presetcustom range►
◄slot_45_start44►
◄slot_45_end44►
◄slot_46_lora_nameno►
◄slot_46_strength1.00►
◄slot_46_presetcustom range►
◄slot_46_start45►
◄slot_46_end45►
◄slot_47_lora_nameno►
◄slot_47_strength1.00►
◄slot_47_presetcustom range►
◄slot_47_start46►
◄slot_47_end46►
◄slot_48_lora_nameno►
◄slot_48_strength1.00►
◄slot_48_presetcustom range►
◄slot_48_start47►
◄slot_48_end47►
◄slot_49_lora_nameno►
◄slot_49_strength1.00►
◄slot_49_presetcustom range►
◄slot_49_start48►
◄slot_49_end48►
◄slot_50_lora_nameno►
◄slot_50_strength1.00►
◄slot_50_presetcustom range►
◄slot_50_start49►
◄slot_50_end49►
◄slot_51_lora_nameno►
◄slot_51_strength1.00►
◄slot_51_presetcustom range►
◄slot_51_start50►
◄slot_51_end50►
◄slot_52_lora_nameno►
◄slot_52_strength1.00►
◄slot_52_presetcustom range►
◄slot_52_start51►
◄slot_52_end51►
◄slot_53_lora_nameno►
◄slot_53_strength1.00►
◄slot_53_presetcustom range►
◄slot_53_start52►
◄slot_53_end52►
◄slot_54_lora_nameno►
◄slot_54_strength1.00►
◄slot_54_presetcustom range►
◄slot_54_start53►
◄slot_54_end53►
◄slot_55_lora_nameno►
◄slot_55_strength1.00►
◄slot_55_presetcustom range►
◄slot_55_start54►
◄slot_55_end54►
◄slot_56_lora_nameno►
◄slot_56_strength1.00►
◄slot_56_presetcustom range►
◄slot_56_start55►
◄slot_56_end55►
◄slot_57_lora_nameno►
◄slot_57_strength1.00►
◄slot_57_presetcustom range►
◄slot_57_start56►
◄slot_57_end56►
◄slot_58_lora_nameno►
◄slot_58_strength1.00►
◄slot_58_presetcustom range►
◄slot_58_start57►
◄slot_58_end57►
◄slot_59_lora_nameno►
◄slot_59_strength1.00►
◄slot_59_presetcustom range►
◄slot_59_start58►
◄slot_59_end58►
◄slot_60_lora_nameno►
◄slot_60_strength1.00►
◄slot_60_presetcustom range►
◄slot_60_start59►
◄slot_60_end59►
◄slot_61_lora_nameno►
◄slot_61_strength1.00►
◄slot_61_presetcustom range►
◄slot_61_start60►
◄slot_61_end60►
◄slot_62_lora_nameno►
◄slot_62_strength1.00►
◄slot_62_presetcustom range►
◄slot_62_start61►
◄slot_62_end61►
◄slot_63_lora_nameno►
◄slot_63_strength1.00►
◄slot_63_presetcustom range►
◄slot_63_start62►
◄slot_63_end62►
◄slot_64_lora_nameno►
◄slot_64_strength1.00►
◄slot_64_presetcustom range►
◄slot_64_start63►
◄slot_64_end63►

The LoRA switchboard for multi-generation Wan loops

Long Wan workflows - SVI-style continuations, multi-scene takes, batch loops - run the same graph many times. Sometimes you want that: the same character LoRA on every pass. Sometimes you want a phase change: a style LoRA on generations 0–3, a different character adapter from generation 4 on, a "cinematic" LoRA only on odd passes. Doing that with static LoRA nodes means duplicating the whole sampling chain per phase. This node replaces the duplication with a schedule.

How it works

Feed it a generation_index (the loop counter - wire forLoopStart.index or your loop's counter into it) and it evaluates up to 64 slots. Each slot has a lora_name, a strength, a preset, and start/end range. On every generation it works out which slots are active and bundles them into a LORA stack output that you feed into IAMCCS_ModelWithLoRA (or the LTX-2 variant) as the stack to apply.

The presets are where the ergonomics live:

  • custom range / manual_range - use slot_start/slot_end; end = -1 means "active from this generation onward."
  • all generations - always on. gen 0 only, gen 1 onwards, even gens, odd gens, every 2nd gen, every 3rd gen - self-explanatory phase patterns.

Slots stack: overlapping active slots combine, so you can have an always-on base LoRA in one slot and phase LoRAs layering on top. model_type (flow/wan2x/standard) controls the key-remapping logic for the stack, matching the rest of the pack's WAN LoRA system.

Outputs: lora (the resolved stack for this generation), active_slots (how many fired - a great sanity check), report (which slot, preset, LoRA, and strength ran on this pass), and a linx contract object.

The hook mechanics

Two implementation details actually matter if you're debugging:

  • IS_CHANGED returns NaN, so the node re-executes every iteration instead of caching - required, because the schedule output changes per generation even though the graph didn't.
  • The check_lazy_status method forces the executor to evaluate the upstream loop start before schedule() runs, so generation_index is always the real iteration index and never None. That's a workaround for a ComfyUI lazy-validation quirk; you don't need to do anything, but if you ever see a "generation_index is None" error, it's this protocol failing, and recreating the node usually fixes it.

In the real world

Install via the pack: ComfyUI Manager (search "IAMCCS") or clone IAMCCS/IAMCCS-nodes into custom_nodes, restart. Keep your always-on LoRAs in the pack's IAMCCS_WanLoRAStack and use this node only for the phase LoRAs - that keeps the schedule readable. And read the report output before you trust a run: "active_slots=2" with the wrong names in the report is usually a preset typo, and it's the fastest way to catch a schedule that silently applied nothing.

CategoryIAMCCS/LoRA

Inputs (325)

NameTypeDefaultDescription
generation_indexINT00–1000000—
log_prefixSTRINGWAN LoRA schedule—
model_typeCOMBOflow3 options: wan2x, flow, standard
slot_01_lora_nameCOMBOno1 options: no
slot_01_strengthFLOAT1.00-5–5—
slot_01_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_01_startINT00–1000000—
slot_01_endINT0-1–1000000—
slot_02_lora_nameCOMBOno1 options: no
slot_02_strengthFLOAT1.00-5–5—
slot_02_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_02_startINT10–1000000—
slot_02_endINT1-1–1000000—
slot_03_lora_nameCOMBOno1 options: no
slot_03_strengthFLOAT1.00-5–5—
slot_03_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_03_startINT20–1000000—
slot_03_endINT2-1–1000000—
slot_04_lora_nameCOMBOno1 options: no
slot_04_strengthFLOAT1.00-5–5—
slot_04_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_04_startINT30–1000000—
slot_04_endINT3-1–1000000—
slot_05_lora_nameCOMBOno1 options: no
slot_05_strengthFLOAT1.00-5–5—
slot_05_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_05_startINT40–1000000—
slot_05_endINT4-1–1000000—
slot_06_lora_nameCOMBOno1 options: no
slot_06_strengthFLOAT1.00-5–5—
slot_06_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_06_startINT50–1000000—
slot_06_endINT5-1–1000000—
slot_07_lora_nameCOMBOno1 options: no
slot_07_strengthFLOAT1.00-5–5—
slot_07_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_07_startINT60–1000000—
slot_07_endINT6-1–1000000—
slot_08_lora_nameCOMBOno1 options: no
slot_08_strengthFLOAT1.00-5–5—
slot_08_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_08_startINT70–1000000—
slot_08_endINT7-1–1000000—
slot_09_lora_nameCOMBOno1 options: no
slot_09_strengthFLOAT1.00-5–5—
slot_09_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_09_startINT80–1000000—
slot_09_endINT8-1–1000000—
slot_10_lora_nameCOMBOno1 options: no
slot_10_strengthFLOAT1.00-5–5—
slot_10_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_10_startINT90–1000000—
slot_10_endINT9-1–1000000—
slot_11_lora_nameCOMBOno1 options: no
slot_11_strengthFLOAT1.00-5–5—
slot_11_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_11_startINT100–1000000—
slot_11_endINT10-1–1000000—
slot_12_lora_nameCOMBOno1 options: no
slot_12_strengthFLOAT1.00-5–5—
slot_12_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_12_startINT110–1000000—
slot_12_endINT11-1–1000000—
slot_13_lora_nameCOMBOno1 options: no
slot_13_strengthFLOAT1.00-5–5—
slot_13_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_13_startINT120–1000000—
slot_13_endINT12-1–1000000—
slot_14_lora_nameCOMBOno1 options: no
slot_14_strengthFLOAT1.00-5–5—
slot_14_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_14_startINT130–1000000—
slot_14_endINT13-1–1000000—
slot_15_lora_nameCOMBOno1 options: no
slot_15_strengthFLOAT1.00-5–5—
slot_15_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_15_startINT140–1000000—
slot_15_endINT14-1–1000000—
slot_16_lora_nameCOMBOno1 options: no
slot_16_strengthFLOAT1.00-5–5—
slot_16_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_16_startINT150–1000000—
slot_16_endINT15-1–1000000—
slot_17_lora_nameCOMBOno1 options: no
slot_17_strengthFLOAT1.00-5–5—
slot_17_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_17_startINT160–1000000—
slot_17_endINT16-1–1000000—
slot_18_lora_nameCOMBOno1 options: no
slot_18_strengthFLOAT1.00-5–5—
slot_18_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_18_startINT170–1000000—
slot_18_endINT17-1–1000000—
slot_19_lora_nameCOMBOno1 options: no
slot_19_strengthFLOAT1.00-5–5—
slot_19_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_19_startINT180–1000000—
slot_19_endINT18-1–1000000—
slot_20_lora_nameCOMBOno1 options: no
slot_20_strengthFLOAT1.00-5–5—
slot_20_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_20_startINT190–1000000—
slot_20_endINT19-1–1000000—
slot_21_lora_nameCOMBOno1 options: no
slot_21_strengthFLOAT1.00-5–5—
slot_21_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_21_startINT200–1000000—
slot_21_endINT20-1–1000000—
slot_22_lora_nameCOMBOno1 options: no
slot_22_strengthFLOAT1.00-5–5—
slot_22_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_22_startINT210–1000000—
slot_22_endINT21-1–1000000—
slot_23_lora_nameCOMBOno1 options: no
slot_23_strengthFLOAT1.00-5–5—
slot_23_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_23_startINT220–1000000—
slot_23_endINT22-1–1000000—
slot_24_lora_nameCOMBOno1 options: no
slot_24_strengthFLOAT1.00-5–5—
slot_24_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_24_startINT230–1000000—
slot_24_endINT23-1–1000000—
slot_25_lora_nameCOMBOno1 options: no
slot_25_strengthFLOAT1.00-5–5—
slot_25_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_25_startINT240–1000000—
slot_25_endINT24-1–1000000—
slot_26_lora_nameCOMBOno1 options: no
slot_26_strengthFLOAT1.00-5–5—
slot_26_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_26_startINT250–1000000—
slot_26_endINT25-1–1000000—
slot_27_lora_nameCOMBOno1 options: no
slot_27_strengthFLOAT1.00-5–5—
slot_27_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_27_startINT260–1000000—
slot_27_endINT26-1–1000000—
slot_28_lora_nameCOMBOno1 options: no
slot_28_strengthFLOAT1.00-5–5—
slot_28_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_28_startINT270–1000000—
slot_28_endINT27-1–1000000—
slot_29_lora_nameCOMBOno1 options: no
slot_29_strengthFLOAT1.00-5–5—
slot_29_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_29_startINT280–1000000—
slot_29_endINT28-1–1000000—
slot_30_lora_nameCOMBOno1 options: no
slot_30_strengthFLOAT1.00-5–5—
slot_30_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_30_startINT290–1000000—
slot_30_endINT29-1–1000000—
slot_31_lora_nameCOMBOno1 options: no
slot_31_strengthFLOAT1.00-5–5—
slot_31_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_31_startINT300–1000000—
slot_31_endINT30-1–1000000—
slot_32_lora_nameCOMBOno1 options: no
slot_32_strengthFLOAT1.00-5–5—
slot_32_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_32_startINT310–1000000—
slot_32_endINT31-1–1000000—
slot_33_lora_nameCOMBOno1 options: no
slot_33_strengthFLOAT1.00-5–5—
slot_33_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_33_startINT320–1000000—
slot_33_endINT32-1–1000000—
slot_34_lora_nameCOMBOno1 options: no
slot_34_strengthFLOAT1.00-5–5—
slot_34_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_34_startINT330–1000000—
slot_34_endINT33-1–1000000—
slot_35_lora_nameCOMBOno1 options: no
slot_35_strengthFLOAT1.00-5–5—
slot_35_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_35_startINT340–1000000—
slot_35_endINT34-1–1000000—
slot_36_lora_nameCOMBOno1 options: no
slot_36_strengthFLOAT1.00-5–5—
slot_36_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_36_startINT350–1000000—
slot_36_endINT35-1–1000000—
slot_37_lora_nameCOMBOno1 options: no
slot_37_strengthFLOAT1.00-5–5—
slot_37_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_37_startINT360–1000000—
slot_37_endINT36-1–1000000—
slot_38_lora_nameCOMBOno1 options: no
slot_38_strengthFLOAT1.00-5–5—
slot_38_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_38_startINT370–1000000—
slot_38_endINT37-1–1000000—
slot_39_lora_nameCOMBOno1 options: no
slot_39_strengthFLOAT1.00-5–5—
slot_39_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_39_startINT380–1000000—
slot_39_endINT38-1–1000000—
slot_40_lora_nameCOMBOno1 options: no
slot_40_strengthFLOAT1.00-5–5—
slot_40_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_40_startINT390–1000000—
slot_40_endINT39-1–1000000—
slot_41_lora_nameCOMBOno1 options: no
slot_41_strengthFLOAT1.00-5–5—
slot_41_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_41_startINT400–1000000—
slot_41_endINT40-1–1000000—
slot_42_lora_nameCOMBOno1 options: no
slot_42_strengthFLOAT1.00-5–5—
slot_42_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_42_startINT410–1000000—
slot_42_endINT41-1–1000000—
slot_43_lora_nameCOMBOno1 options: no
slot_43_strengthFLOAT1.00-5–5—
slot_43_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_43_startINT420–1000000—
slot_43_endINT42-1–1000000—
slot_44_lora_nameCOMBOno1 options: no
slot_44_strengthFLOAT1.00-5–5—
slot_44_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_44_startINT430–1000000—
slot_44_endINT43-1–1000000—
slot_45_lora_nameCOMBOno1 options: no
slot_45_strengthFLOAT1.00-5–5—
slot_45_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_45_startINT440–1000000—
slot_45_endINT44-1–1000000—
slot_46_lora_nameCOMBOno1 options: no
slot_46_strengthFLOAT1.00-5–5—
slot_46_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_46_startINT450–1000000—
slot_46_endINT45-1–1000000—
slot_47_lora_nameCOMBOno1 options: no
slot_47_strengthFLOAT1.00-5–5—
slot_47_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_47_startINT460–1000000—
slot_47_endINT46-1–1000000—
slot_48_lora_nameCOMBOno1 options: no
slot_48_strengthFLOAT1.00-5–5—
slot_48_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_48_startINT470–1000000—
slot_48_endINT47-1–1000000—
slot_49_lora_nameCOMBOno1 options: no
slot_49_strengthFLOAT1.00-5–5—
slot_49_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_49_startINT480–1000000—
slot_49_endINT48-1–1000000—
slot_50_lora_nameCOMBOno1 options: no
slot_50_strengthFLOAT1.00-5–5—
slot_50_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_50_startINT490–1000000—
slot_50_endINT49-1–1000000—
slot_51_lora_nameCOMBOno1 options: no
slot_51_strengthFLOAT1.00-5–5—
slot_51_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_51_startINT500–1000000—
slot_51_endINT50-1–1000000—
slot_52_lora_nameCOMBOno1 options: no
slot_52_strengthFLOAT1.00-5–5—
slot_52_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_52_startINT510–1000000—
slot_52_endINT51-1–1000000—
slot_53_lora_nameCOMBOno1 options: no
slot_53_strengthFLOAT1.00-5–5—
slot_53_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_53_startINT520–1000000—
slot_53_endINT52-1–1000000—
slot_54_lora_nameCOMBOno1 options: no
slot_54_strengthFLOAT1.00-5–5—
slot_54_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_54_startINT530–1000000—
slot_54_endINT53-1–1000000—
slot_55_lora_nameCOMBOno1 options: no
slot_55_strengthFLOAT1.00-5–5—
slot_55_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_55_startINT540–1000000—
slot_55_endINT54-1–1000000—
slot_56_lora_nameCOMBOno1 options: no
slot_56_strengthFLOAT1.00-5–5—
slot_56_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_56_startINT550–1000000—
slot_56_endINT55-1–1000000—
slot_57_lora_nameCOMBOno1 options: no
slot_57_strengthFLOAT1.00-5–5—
slot_57_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_57_startINT560–1000000—
slot_57_endINT56-1–1000000—
slot_58_lora_nameCOMBOno1 options: no
slot_58_strengthFLOAT1.00-5–5—
slot_58_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_58_startINT570–1000000—
slot_58_endINT57-1–1000000—
slot_59_lora_nameCOMBOno1 options: no
slot_59_strengthFLOAT1.00-5–5—
slot_59_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_59_startINT580–1000000—
slot_59_endINT58-1–1000000—
slot_60_lora_nameCOMBOno1 options: no
slot_60_strengthFLOAT1.00-5–5—
slot_60_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_60_startINT590–1000000—
slot_60_endINT59-1–1000000—
slot_61_lora_nameCOMBOno1 options: no
slot_61_strengthFLOAT1.00-5–5—
slot_61_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_61_startINT600–1000000—
slot_61_endINT60-1–1000000—
slot_62_lora_nameCOMBOno1 options: no
slot_62_strengthFLOAT1.00-5–5—
slot_62_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_62_startINT610–1000000—
slot_62_endINT61-1–1000000—
slot_63_lora_nameCOMBOno1 options: no
slot_63_strengthFLOAT1.00-5–5—
slot_63_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_63_startINT620–1000000—
slot_63_endINT62-1–1000000—
slot_64_lora_nameCOMBOno1 options: no
slot_64_strengthFLOAT1.00-5–5—
slot_64_presetCOMBOcustom range9 options: custom range, manual_range, all generations, gen 0 only, gen 1 onwards, even gens (0,2,4...), +3
slot_64_startINT630–1000000—
slot_64_endINT63-1–1000000—
default_loraoptLORA—
linxoptIAMCCS_WAN_LORA_LINX—

Outputs (4)

NameTypeDescription
loraLORA—
active_slotsINT—
reportSTRING—
linxIAMCCS_WAN_LORA_LINX—